KP-ART206 Self-adaption Fault Information Sub-station Test System
- 品牌 KETOP
- 型号 KP-ART206
Self-adaption test system, a leap from complicated to simple
ART206 Self-adaption Fault Information Sub-station Test System omits all actual devices and systems. It makes a comprehensive simulation from Substation bay level to Protection and Fault Information Management master-station, moreover, it improves the efficiency of acceptance and turns the tedious work into one-click test.
China Southern Power Grid Protection and Fault Information Management Sub-station net test (30 devices for 4 batches)
China Southern Power Grid relay protection tele-control test (5 sub-station and 80 protection devices)
Function Introduction
1、Automatic high performance closed-loop test
Testing cases can be edited, test process is one-click affair, and report can be generated automatically
Multi-link, such as case design, test drive, information transmission, information check and reports generation, can be automatic cohesion;
Shorten the traditional sub-station test time by 2 days to 0.5 days, greatly improve the working efficiency.
2、Protection and Fault Information Management master-station simulation
Can simulate the communication protocol of domestic main Protection and Fault Information Management master-station, communicate with Protection and Fault Information Management sub-station, and collect analog and binary, setting value, wave record files and other information
3、Adaptive protection device simulation
It can simulate flexibly on Ethernet protocol of IEC60870-5-103 and IEC61850 for mainstream protection manufacturers, and can transmit all kinds of relay protection information and documents to Protection and Fault Information Management sub-station as well.
4、Reliable channel to monitor technology
Large capacity of message monitoring analysis, alarm and search function, and accurate analysis Information Processing.
5、Easy extensibility
It analog layer and distribution design of protection equipment, which is also convenient to expand new types of protection simulation program.
Technical Index
1、more than 10 kinds of protection device of mainstream manufacturers can be simulated, and the protocols are support to extend.
2、more than 50 protection devices can communicate with Protection and Fault Information Management sub-station can be simulated at the same time.
3、Protection and Fault Information Management master-station communicate with sub-station can be simulated at the same time .
4、24 hour uninterrupted communication channel monitoring can achieved on the premise of normal system operation
Test modules